Trane High Efficiency Furnace Problems
If this is the case you ll need your local trane comfort specialist to inspect the ductwork.
Trane high efficiency furnace problems. Your filters may be clogged or dirty clean or replace the filters. If the switch is open you won t get a reading or you ll measure infinite ohms. Trane 95 and 90 gas furnaces deliver at least 90 efficiency far exceeding the government minimum standard of 80 afue for new furnaces. If you have a furnace that is at least 10 years old it probably has an afue somewhere between 60 and 70 meaning up to 40 cents of every dollar you pay for fuel is wasted.
For your indoor air handler try to wipe away any buildup of dust on the coil and change the air filter often. This is the reason why no fossil fuel furnace sold has a rating of up to 100. Gas or oil furnaces generally cannot achieve efficiency at 100 because of impurities in the fuel including moisture. If the switch is closed you ll get a reading between the two terminals.
There could also be a blockage in your air ducts. If you re looking for efficiency you probably want to choose a gas furnace. When a furnace is installed so that supply ducts carry air circulated by the furnace to areas outside the space containing the furnace the return air shall also be handled by a duct s sealed to the furnace casing and terminating outside the space containing the furnace. Your indoor air handler coil could be blocked ordinary house dust and debris like soot or pollen can block indoor air handler coils.
A gas fired furnace for installation in a residential garage. During the winter this energy star rated furnace is rated at 97 afue meaning it uses less gas to heat your home versus less efficient models. The s9v2 vs furnace includes features to maximize your home efficiency in both heating and the cooling seasons. Try changing the air filters.
It is also called a trane 90 plus gas furnace because it offers efficiency levels up to 90 percent plus afue rating. The pilot light may have gone out the pilot light is a small flame that ignites the main furnace flame. This is one of the quietest oil furnaces on the market with so many features that help reduce noise. Your owner s manual will feature detailed instructions on re lighting the pilot.
Obstructed intake air vent improper exhaust gas recirculation clogged condensate drain clogged flue vent faulty pressure switch. As expected since it s an oil furnace this is not the most energy efficient option out there. Why is there no heat coming from my gas furnace. If it s open when the furnace is cold it s bad and needs to be replaced.